Client
The client requested an RO (Reverse Osmosis) water treatment system to supply HDF (Ultra-Pure) permeate water for a 22-bed dialysis unit.
Marlin Technologies Group proposed a static, dual-pass, indirect-feed RO system to produce 1000 liters/hr
Source
Municipal
Water Treatment System:
Pre RO filtration
- Media Filtration
- Water Softening
- Chlorine Removal
Reverse Osmosis Machine
- Dual-pass configuration to produce 1000 liters/hr permeate to meet HDF quality
Post RO filtration
- Conical pure water storage tank
- Ultraviolet sterilization
- Bacterial filtration
Benefits
- Water savings – Based on system design
- 24/7 technical support
- Water quality management